NBANDS = 1 CALL TOBCF(NBANDS,MINB,MAXB,FREQ) or NBANDS = 2 CALL TOBCF(NBANDS,FMIN,FMAX,FREQ) -- This subroutine calculates the 1/3 octave band center frequencies. The range of frequencies is determined by NBANDS. FCTR: TO NBANDS - If NBANDS = 1, the next two arguments are taken as the minimum and maximum band numbers. If NBANDS = 2, the next two arguments are taken to be the minimum and maximum frequencies. On return NBANDS is the number of bands calculated. MINB,MAXB - Mimimum and maximum band numbers if NBANDS = 1. FMIN,FMAX - Minimum and maximum frequencies if NBANDS = 2. FREQ - Calculated 1/3 octave band center frequencies.